OROLIN® Multisept Plus

Powerful disinfectant concentrate for medical and dental instruments.

250 ml bottle 1 litre bottle with measuring cap 2 litre bottle with measuring cap 5 litre canister 5 litre canister
250 ml bottle 1 litre bottle with measuring cap 2 litre bottle with measuring cap 5 litre canister 5 litre canister

OROLIN® Multisept Plus

OROLIN® Multisept Plus is a powerful concentrate for the manual disinfection and cleaning of medical and dental instruments made of stainless steel, tungsten carbide, diamond grit, titanium, silicon carbide, and silicone. Also suitable for alcohol-sensitive rotary instruments. OROLIN® Multisept Plus is free of aldehydes, phenols, and chlorine.

Delivery forms

Documents

Where to buy

Explore OROLIN® Multisept Plus's Features and Benefits

Kills 101 microorganisms

Active against even the most resistant viruses incl. adenovirus, norovirus and poliovirus.

Fully virucidal within 15 minutes

Active against bacteria, mycobacteria, yeasts as well as enveloped and non-enveloped viruses within 15 minutes.

High-yielding concentrate

2 litre of concentrate yields 100 litres of working solution

Suitable for use in ultrasonic cleaning devices

The cleansing power of the disinfectant can be further increased using an ultrasonic cleaning device.

Maximum cost-effectiveness

The disinfectant is available in 5-litre canisters to reduce waste and offer better value for money.

Dosing table

The bottle cap contains volume markings for 10 ml, 20 ml, 30 ml, and 40 ml.

Aldehyde-, phenol- and chlorine-free

The aldehyde-, phenol- and chlorine-free formula minimises the risk of allergies and skin irritations.

Ensuring the Compatibility of Our Disinfectants Is a Top Priority

While no disinfectant can guarantee absolute compatibility with all materials, our rigorous in-house testing, strategic collaborations with medical device manufacturers, and stringent external testing at ISO 17025 accredited laboratories for final material compatibility evaluations—affirm that our disinfectants are exceptionally suited for a broad spectrum of surfaces, encompassing various metals, plastics, and polymers.
Note
  • No visible surface damage or effect on the material is likely to occur when used according to label directions. No change to the integrity of the material is expected.
  • Some visible surface damage such as tarnishing or clouding may be seen with long-term exposure. Little to no effect on material intergrity is expected. Periodic wiping of surfaces with a clean damp cloth to remove residue can help to minimize damage.
  • Visible damage to the surface is likely to occur with long-term exposure and some effect on material integrity is possible. Surfaces should be wiped with a clean damp cloth immediately after the contact time has been reached to reduce the risk of damage. Users should evaluate the risk of surface damage vs the benefits of disinfectant efficacy against pathogens to determine whether the products is appropriate for use.

The Diversity of Materials in Healthcare – From Metals to Polymers – Makes Compatibility with Disinfectants and Cleaners Crucial

Recognizing and addressing material incompatibilities is of paramount significance in the medical industry. The utilization of disinfectants and cleaners that are not harmonious with specific materials can result in detrimental outcomes, including material degradation, corrosion, or impaired functionality in essential healthcare instruments. These incompatibilities can induce chemical reactions, hasten wear and tear, and ultimately curtail the useful lifespan of these critical tools. Furthermore, material degradation or corrosion can establish an optimal environment for pathogenic proliferation, thereby compromising the disinfection and cleaning processes designed to uphold the sterility of healthcare environments. Consequently, the effectiveness and durability of healthcare instruments are contingent not only on their manufacturing quality but also on the intricate interaction between the materials comprising them and the disinfectants and cleaners applied to preserve their structural integrity and
safety.

The Challenge of Degradation, Corrosion, or Loss of Functionality

The healthcare industry encounters substantial challenges when it comes to disinfecting and cleaning medical instruments, primarily due to the extensive array of materials employed in these tools. The paramount objective is to eradicate pathogens effectively while safeguarding the integrity and functionality of these instruments.

A significant hurdle in healthcare revolves around the potential harm that specific disinfectants and cleaners can cause to diverse instrument materials. The chemical interactions between disinfectants, cleaners, and instrument materials can result in corrosion, structural harm, or diminished performance. For instance, chlorine-based disinfectants and cleaners can erode metals like stainless steel, alcohol-based solutions may render plastics and rubber fragile, and quaternary ammonium compounds (Quats) can leave residues that adversely impact instrument performance.

The resolution for addressing the degradation, corrosion, and functional loss of healthcare instruments hinges on a collaborative approach. Instrument manufacturers must prioritize the use of durable and resilient materials. Simultaneously, disinfectant and cleaner manufacturers should emphasize the formulation of disinfectants and cleaners that are gentle on these materials while maintaining their efficacy.

At Oro Clean Chemie AG, we wholeheartedly embrace this approach as part of our unwavering commitment to excellence in healthcare disinfection. We ensure that our disinfectants and cleaners are not only potent in eliminating pathogens but also compatible with a wide range of healthcare instrument materials. This ensures that healthcare professionals never find themselves in the challenging position of choosing between clinical effectiveness and the longevity of their vital healthcare instruments.

FAQ

  • How is the exposure time determined for disinfectants?
    European standards specify the required exposure times for disinfectants to achieve their claimed efficacy. The standards provide detailed instructions on the duration of contact between the disinfectant and the microorganism to ensure effective inactivation or reduction.
  • What's the main goal of the EN 14885:2022 document, especially in a medical context?
    EN 14885:2022 serves as a comprehensive guide for chemical disinfectants and antiseptics, especially in the medical field. It outlines the standards for testing these products to ensure they are effective and safe for use in various medical settings, like hospitals and clinics. The document helps manufacturers validate their product claims, assists users in selecting appropriate products, and guides regulatory authorities in evaluating these products.
  • Can you explain the difference between 'with mechanical action' and 'without mechanical action' in EN 14885:2022?
    With mechanical action" refers to the process of physically wiping a surface or object with a disinfectant, enhancing the removal of microbes. This is common in settings where thorough cleaning is necessary. "Without mechanical action" means applying the disinfectant without any physical aid, for example through spraying. This method relies solely on the chemical properties of the disinfectant to kill or deactivate microbes. The choice between these methods depends on the specific requirements of the healthcare setting and the type of surface being disinfected.
  • How do I determine if a disinfectant is safe for use on dental equipment with various material components?
    To ensure the safety of dental equipment, you should reference the equipment manufacturer's instructions for care and the disinfectant's material compatibility list. Some dental equipment materials, like certain plastics or silicone, may require specific types of disinfectants to prevent damage.
  • Are there any best practices for testing the compatibility of a new disinfectant with healthcare materials?
    Best practices for testing a new disinfectant include conducting spot tests on a small, inconspicuous area of the material, monitoring for any adverse reactions, and verifying the results against the disinfectant's material compatibility chart. It's also recommended to consult with the disinfectant manufacturer for any specific testing protocols or guidelines they may provide.
  • What is EN ISO 21530 and how does it relate to the use of disinfectants in healthcare?
    EN ISO 21530 is a standard that specifies the requirements and test methods for assessing the compatibility of disinfectants with the materials used in medical devices. Its main objective is to ensure that the physical and chemical properties of medical device materials are maintained even after repeated disinfection processes. This ensures that the products can continue to be used safely and effectively in the healthcare sector.
  • How does EN ISO 21530 influence the selection of disinfectants for medical devices?
    EN ISO 21530 has a significant impact on the selection of medical device disinfectants by providing healthcare providers with clear information on which disinfectants have been thoroughly tested and proven to have no harmful effects on the materials used in their medical devices. This enables professionals to select disinfectants that will not compromise the integrity or functionality of the devices and therefore maintain the highest safety standards.
  • When should I use an ultrasonic device for cleaning and disinfection?
    An ultrasonic device is especially suitable to clean and disinfect heavily contaminated instruments, or to remove stubborn residues such as cement or plaster that persist after disinfection. Following such cleaning, however, the instruments must be disinfected again. Devices with many sensitive parts, such as handpieces, generally cannot be cleaned in an ultrasonic device.
  • Why must instruments be disinfected before sterilization?
    Medical instruments are often sharp and thus pose an increased risk of injury. For this reason, it is important that healthcare professionals always treat used instruments as potentially infectious. The reprocessing cycle should therefore begin with disinfection to protect the staff responsible for further reprocessing steps such as cleaning, inspection, instrument care, sterilization, and packaging. The use of a disinfectant with high cleaning power, such as OROLIN® Multisept Plus, can help reduce or even eliminate the need for manual cleaning.
More FAQs

Getting the Most Out of OROLIN® Multisept Plus

Intended Users

The product is intended for use by dental or healthcare professionals with knowledge about the disinfection of medical devices. The product is not to be used directly on patients.

Instructions for Use

For your protection, wear a laboratory gown, household gloves and safety goggles. Prepare the working solution according to the dosing table. Immerse instruments completely and adhere to contact time. After disinfection, rinse instruments thoroughly under running water of at least drinking quality for 10 seconds. Visually check instruments after the disinfection for contaminants. If necessary, remove contaminants with a brush and repeat the disinfection process. Replace working solution daily or when visibly contaminated. The disinfectant solution is also suitable for use in an ultrasonic cleaning device. Adhere to reprocessing recommendations of the instrument manufacturer. A list of compatible and incompatible materials is available on our website. If you are uncertain as to the material composition of the medical device, contact the manufacturer before use. Any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the Member State in which the user and/or patient is established.

Limitations

FOR PROFESSIONAL USE ONLY. Not for final disinfection of semi-critical and critical medical devices. Sterilize medical devices after disinfection. Do not mix with other products. For virucidal efficacy, perform disinfection on previously cleaned instruments only.

Dosing Table

Concentrate
+
Water
Time
2% 20 ml + 980 ml 15 min

Use Steps

1

For your protection, wear a laboratory gown, household gloves and safety goggles.

2

Prepare the working solution according to the dosing table.

3

Immerse instruments completely and adhere to contact time.

4

After disinfection, rinse instruments thoroughly under running water of at least drinking quality for 10 seconds.

5

Visually check instruments after the disinfection for contaminants.

6

If necessary, remove contaminants with a brush and repeat the disinfection process.

Handling

Danger Danger H302 Harmful if swallowed. H314 Causes severe skin burns and eye damage. H373 May cause damage to organs through prolonged or repeated exposure. H410 Very toxic to aquatic life with long lasting effects. P280 Wear protective gloves/protective clothing/eye protection/face protection. P301 + P312 IF SWALLOWED: Call a POISON CENTER or doctor/physician if you feel unwell. P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P391 Collect spillage. P501 Dispose of contents/container in accordance with local and national regulations. For more information, please refer to Safety Data Sheet available on our website.

Accessories and Application Aids

User Friendly Packaging

Packaging Details

Primary Packaging
Item code
CH-060005
Dimensions (length x width x height)
48.6 mm x 48.6 mm x 175 mm
Gross weight
0.3 kg
Net weight
0.2475 kg
GTIN
9551001440322
Shelf life
48 months
Storage conditions
Store in cool, dry and well-ventilated facility. Keep out from direct sunlight, heat, and open flame. Storage temperature: < 30°C
Packaging features

Flip-Top Closure

The flip-top closure allows healthcare professions to easily dispense the product onto a cloth without creating aerosols, thereby minimizing the risk of respiratory irritation and ensuring a safer application.

Label with Image of Application Area

The label includes an image for the product's application area, minimizing the potential of using the wrong product, especially in hectic working environments.

Tamper-Evident Closure

The tamper-evident closure guarantees the integrity of the product and provides the assurance that it has not been opened or contaminated.

Bottles Made of Recyclable HD-PE Material

Promotes environmental sustainability by ensuring the packaging can be fully recycled, safeguarding resources for future generations.

 Secondary Packaging
Quantity per carton
25 pieces
Dimensions (length x width x height)
273 cm x 258 cm x 236 cm
Weight
7.5 kg
GTIN
9551001440940
Pallet
Number of layers
6
Number of boxes per layer
12
Quantity per pallet
1800
Dimensions (length x width)
One way pallet: 177 cm x 77 cm
GTIN
9551001444412

Discover More About OROLIN® Multisept Plus

Composition in 100g

100 g contains 9.1 g alkylamine, 3.6 g didecyldimethylammonium chloride, corrosion inhibitors, auxiliaries and water.

Physical and Chemical Properties

Physical state
Liquid
Form
Clear, slightly viscous liquid
Colour
Blue
Odour
Aromatic
Flammability
The product is not flammable.
Lower explosion limit
Not applicable.
Upper explosion limit
Not applicable.
Auto-ignition temperature
Not self-igniting.
pH-value (undiluted product)
11.5 - 13.0
pH-value (diluted product)
10.0 - 11.5 (2%)
Solubility
Completely miscible with water.
Partition coefficient n-octanol/water
Not applicable.
Density
0.99 g/cm3
Relative density
0.99
Oxidising properties
Not oxidising.
Explosive properties
Product is not explosive.
Miscibility
Completely miscible with water.